SXDOOL 804 Enclosure Filter Fan Kit with Rain Hood and Thermostat, 206 × 206 × 136 mm
Fit a filtered intake and rain hood to a 175 × 175 mm cabinet cutout. This kit pairs a preassembled EC filter fan with an SXD011 thermostat, a CH-2 connector and a 1.5 m US power cord.
Low minimum order quantities and short production lead times are available for OEM builds. Ask about cable, connector, label and packaging options or request pricing for a production run. Request a quote for the 804 kit.
| Model | 804-SXDE17251HB-KIT |
|---|---|
| Overall dimensions | 206 × 206 × 136 mm |
| Panel cutout | 175 × 175 mm |
| Fan component | SXDE17251HB |
| Fan dimensions | 172 × 150 × 51 mm |
| Voltage | 115 V / 230 V AC, 50/60 Hz |
| Speed | 3,500 RPM ±10% |
| Airflow | 260 CFM (fan rating) |
| Noise | 59 dBA (fan rating) |
| Power | 32 W (fan rating) |
| Thermostat | SXD011 |
| Connector | CH-2 |
| Power cord | 1.5 m, US two-blade plug |
| Minimum order quantity | Low MOQ. Confirmed in the quotation for the requested configuration. |
| Single-kit package dimensions | 23 × 23 × 15 cm |
| Gross packaged weight | 1.3 kg |
Filtered ventilation for outdoor control cabinets
The 804 fits electrical enclosures that need a covered ventilation opening. The hood sits outside the cabinet, shielding the opening from direct rain. Air enters beneath the hood and passes through the filter. For an outdoor installation, include the mounting orientation, exposure and required enclosure protection rating in your project specification.

Panel cutout and service clearance
Use a 175 × 175 mm square opening. The assembled hood and fan measure 206 mm wide × 206 mm high × 136 mm deep overall. Check the drawing against the available clearance on both sides of the panel and leave access for wiring and filter service.

What ships in the standard kit?
- One preassembled 804 rain hood and filter, SXDE17251HB EC fan, metal fan guard and mounting screws.
- One separate SXD011 thermostat.
- One separate CH-2 connector.
- One 1.5 m power cord with a US two-flat-blade plug.

Technical specifications
| Complete kit part number | 804-SXDE17251HB-KIT |
|---|---|
| Overall assembly (W × H × D) | 206 × 206 × 136 mm |
| Cabinet panel cutout | 175 × 175 mm |
| Fan model and frame | SXDE17251HB, 172 × 150 × 51 mm |
| Fan supply | 115 V / 230 V AC, 50/60 Hz |
| Fan airflow | 260 CFM |
| Fan speed | 3,500 RPM ±10% |
| Fan power | 32 W |
| Fan noise level | 59 dBA |
| Single-kit package (L × W × H) | 23 × 23 × 15 cm |
| Gross packaged weight | 1.3 kg |
The 260 CFM, speed, power and noise figures apply to the fan. Filter resistance and the cabinet air path affect installed airflow. Include the airflow and operating pressure your equipment requires when requesting a fan selection.
Specify the project supply voltage and destination when ordering. Check the fan marking against the cabinet supply before wiring.

OEM options for pilot and production runs
Keep the standard kit for a pilot build, or send a cable drawing, connector reference, label artwork or packaging specification for review. SXDOOL supports low minimum order quantities and short production lead times. We confirm the minimum order and production schedule for your configuration in the quote.

Bulk pricing and project quotations
Bulk pricing is negotiable by quantity and configuration. Include your panel drawing, supply voltage, initial order quantity, forecast volume, destination and target delivery date. We can quote the pilot and production quantities separately so your purchasing team can compare unit prices and schedules.

Request a quote for the 804 kit.
804 kit selection and ordering questions
What panel cutout does the 804 enclosure filter fan kit require?
Use a 175 × 175 mm panel cutout. The complete hooded assembly measures 206 × 206 × 136 mm. Check the available depth, wiring space and filter access before cutting.
How should I compare airflow when selecting filter fans for enclosures?
The SXDE17251HB fan is rated at 260 CFM. Filter resistance and the cabinet air path affect delivered airflow. When comparing enclosure filter fans, ask for airflow at the pressure your design requires.
What comes assembled, and which parts are loose?
The 804 rain hood, filter, EC fan, metal guard and screws arrive assembled. The box also contains one separate SXD011 thermostat, one CH-2 connector and one 1.5 m US power cord with two flat blades.
Does this control cabinet fan kit include a thermostat?
Yes. One SXD011 thermostat is included as a separate part. Plan its mounting and wiring with the CH-2 connector as part of the enclosure design.
What voltage and frequency should I specify?
The SXDE17251HB fan specification lists 115 V / 230 V AC, 50/60 Hz. Include your supply voltage and destination in the quotation request to confirm the configuration.
How do I select the kit for an outdoor control cabinet?
Specify how the cabinet will be mounted, where rain may reach it and what protection rating your project requires. The hood covers the filter opening. Verify protection for the complete enclosure and installation.
Can I order a small batch of custom 804 kits?
Yes. We offer low minimum order quantities for OEM orders. Share the quantity you need and any changes to the cable, connector, label or packaging. We review the requested changes and confirm the minimum for that configuration.
How soon can my custom kits ship, and how is a bulk order priced?
Short production lead times are available. Send your order quantity, required ship date and destination. We confirm the production schedule after reviewing your configuration and quote transit time separately. Bulk pricing is negotiable by quantity and configuration.
Related products
SXDOOL 801EC8025 IP54 Filter Fan Kit | 80mm
801EC8025 IP54 enclosure filter fan kit for compact cabinet ventilation where mounting depth is limited. Select 12V DC, 24V DC, 115/230V AC, 50/60 Hz; fan-rated airflow reaches 42.5 CFM depending on the selected version. Confirm panel cutout, supply voltage, airflow direction and quantity for a factory RFQ.
SXDOOL 801EC8038 IP54 Filter Fan Kit 80x80x38mm
801EC8038 IP54 enclosure filter fan kit for compact control cabinets that need more airflow from the same 801-series panel opening. Select 12V DC, 24V DC, 115/230V AC, 50/60 Hz; fan-rated airflow reaches 83.5 CFM depending on the selected version. Confirm panel cutout, supply voltage, airflow direction and quantity for a factory RFQ.
SXDOOL 802EC9225 IP54 Filter Fan Kit 92x92x25mm
802EC9225 IP54 enclosure filter fan kit for medium-small PLC and automation cabinets where a shallow 92 mm fan platform is preferred. Select 12V DC, 24V DC, 115/230V AC, 50/60 Hz; fan-rated airflow reaches 74 CFM depending on the selected version. Confirm panel cutout, supply voltage, airflow direction and quantity for a factory RFQ.
SXDOOL 803EC1225 IP54 Filter Fan Kit | 12025
803EC1225 IP54 enclosure filter fan kit for control cabinets that need a 120 mm fan platform with reduced installation depth. Select 12V DC, 24V DC, 115/230V AC, 50/60 Hz; fan-rated airflow reaches 135.5 CFM depending on the selected version. Confirm panel cutout, supply voltage, airflow direction and quantity for a factory RFQ.
SXDOOL 804EC17251 IP54 Filter Fan Kit | 172mm
804EC17251 IP54 enclosure filter fan kit for larger electrical cabinets and switchgear requiring up to 208.2 CFM fan-rated airflow. Select 12V DC, 24V DC; fan-rated airflow reaches 208.2 CFM depending on the selected version. Confirm panel cutout, supply voltage, airflow direction and quantity for a factory RFQ.