SXDOOL 9238 92x92x38mm EC Axial Fan AC Input
SXDOOL 9238 92x92x38mm EC axial fan for compact servers and filtered boxes. Confirm AC input range, speed-control need, airflow, noise, bearing, connector, certification and quantity with SXDOOL for OEM samples, cable, connector, bearing, label and batch RFQ review.
SXDOOL 9238 EC fan for AC-powered higher-resistance enclosures
Engineering summary: This 92x92x38mm EC platform provides 57.1-79.9CFM and 4.2-8.9mmH2O catalog grades from a 100-264V operating range. The thicker frame gives more pressure reserve than 9225 EC while retaining an AC-input electronically commutated architecture.
| Product / model reference | SXDE9238HB / SXDE9238MX / SXDE9238LX |
|---|---|
| Fan family | Electronically commutated axial fan with AC input |
| Dimensions | 92x92x38mm |
| Input platform | 115/230V rated family, 50/60Hz, 100-264V operating range |
| Bearing selection | Sleeve or ball-bearing family options; final bearing and complete model suffix must follow the approved production drawing |
| Control / wiring boundary | Do not infer low-voltage DC PWM, FG, RD, polarity, or connector behavior. Use the approved EC wiring diagram and host safety design |
| Material / flammability boundary | Catalog family reference: plastic frame and impeller, UL94V-0. Final resin and compliance documentation must match the approved production specification |
| Catalog operating environment | -10 to 70C operation, 35%-85%RH; -40 to 80C storage, 35%-85%RH. Validate mains, derating, surge, and condensation conditions |
| Application fit | AC-powered automation cabinets, electrical enclosures, UPS equipment, and industrial control systems with a 92mm opening and a moderately restrictive airflow path. |
| Page differentiation | This is the 38mm EC platform. Compare 9225 EC where depth is limited and 9238 DC where the host provides 12V, 24V, or 48V DC. |
| Manufacturer and quality review | SENSDA ELECTRONICS LIMITED / SXDOOL. ISO 9001:2015 quality-management documentation, OEM/ODM cable and connector requirements, Dynamic Balancing, and 100% End-of-Line Testing can be reviewed against the approved production control plan. |
| Source and qualification boundary | EC family values are catalog-typical under nominal voltage. Catalog noise is referenced one meter from the air intake. Current approved model documents and samples govern the final specification. |
Model and configuration table
| Model grade | Input range | Frequency | Current | Power | Speed | Airflow | Static pressure | Noise |
|---|---|---|---|---|---|---|---|---|
| SXDE9238HB | 115/230V; 100-264V operating range | 50/60Hz | 0.07A | 7.0W | 3500RPM | 79.9CFM | 8.9mmH2O | 37dBA |
| SXDE9238MX | 115/230V; 100-264V operating range | 50/60Hz | 0.05A | 5.0W | 3000RPM | 68.5CFM | 6.8mmH2O | 33dBA |
| SXDE9238LX | 115/230V; 100-264V operating range | 50/60Hz | 0.03A | 4.0W | 2500RPM | 57.1CFM | 4.2mmH2O | 29dBA |
Image evidence reconciliation: The photographed product label identifies SXDE9238MB at AC 115/230V, 50/60Hz and 5W. The controlled 9238 catalog instead lists the 5W medium grade as SXDE9238MX at 3000RPM, 68.5CFM, 6.8mmH2O and 33dBA. Those catalog values must not be assigned to the photographed MB configuration by assumption. Historical graphics citing 3200RPM, 186g, a 90-270V range, generic dual-ball construction or a 50,000-hour lifetime were removed because they conflict with the controlled catalog or lack model-specific qualification evidence.
Engineering release rule: Catalog values are typical reference data under nominal test conditions. The current approved drawing, controlled datasheet, sample label, and validated equipment test govern the final purchasable configuration.
Model-specific engineering FAQ
What duty-point and pressure-loss evidence supports choosing 9238 EC over 9225 EC?
Use a measured system curve or representative test to show that the 25mm platform cannot meet the required airflow at the enclosure resistance. Confirm that the additional 13mm depth and the EC input wiring can be accommodated before selecting 9238.
How should an enclosure designer validate the 68.5CFM MX catalog value at the operating point?
Treat it as a free-air reference for the catalog grade, not the installed cabinet airflow. The actual result depends on filters, louvers, plenum geometry, component blockage, and outlet area, so validate the operating point with the complete assembly.
What mounting clearance and IP-rated enclosure airflow path are required for 9238 EC?
A bare axial fan opening changes the enclosure protection concept. If ingress protection is required, qualify the complete fan, grille, filter, gasket, cutout, mounting, and maintenance design; do not assign an IP rating from the motor type alone.
Which wiring, voltage and production-release checks are required for 9238 EC in 24-hour service?
Confirm bearing selection, input conditions, ambient temperature, dust loading, mounting orientation, start-stop profile, filter-service interval, vibration, and the approved lifetime basis. Then run representative endurance and blocked-filter tests.
Continue with the fan selector, review compare the thinner 9225 EC platform, review the 802EC9238 filter fan kit, or submit a model-specific RFQ.
Brand: SXDOOL. English company name: SENSDA ELECTRONICS LIMITED. Chinese company name: 广州市盛煊达电子科技有限公司. Chinese pinyin: Guangzhoushi Shengxuanda Electronics Technology Co.,Ltd. External inquiry: david@sxdool.com.